Close Menu
    What's Hot

    Boao Forum: CRRC Zhuzhou Institute Outlines Core Technologies and Application-Driven Innovation for Green Industry Growth

    August 4, 2026

    Australia reforms National Disability Insurance Scheme rules

    August 1, 2026

    India commits 84084 crore rupees to offshore energy security

    August 1, 2026
    Facebook X (Twitter) Instagram
    Maghreb GuardianMaghreb Guardian
    • Automotive
    • Business
    • Entertainment
    • Health
    • Lifestyle
    • Luxury
    • News
    • Sports
    • Technology
    • Travel
    Maghreb GuardianMaghreb Guardian
    Home » CLOU Releases White Paper on Active Ventilation & Explosion-Proof System Following Landmark 59-Hour Large-Scale Fire Test
    PR Newswire

    CLOU Releases White Paper on Active Ventilation & Explosion-Proof System Following Landmark 59-Hour Large-Scale Fire Test

    July 24, 2025
    Facebook Twitter LinkedIn Telegram Pinterest Tumblr Reddit WhatsApp Email
    Share
    Facebook Twitter LinkedIn Pinterest Email

    SHENZHEN, China, July 24, 2025 /PRNewswire/ — CLOU, a BNEF Tier 1 energy storage system provider, has officially released its White Paper on Active Ventilation & Explosion-Proof System, offering an in-depth look into the company’s next-generation fire safety architecture for energy storage systems. The release follows the successful completion of a 59-hour and 10-minute Large-Scale Fire Test of its 5MWh Aqua C2.5 liquid-cooled BESS in April.

    The large-scale fire test, fully witnessed and documented by CSA Group, simulated an extreme thermal runaway scenario. Four fully loaded Aqua C2.5 containers (A/B/C/D), forming a 20MWh system, were installed back-to-back and side-by-side to replicate actual high-density station layouts. Container A was intentionally ignited and sustained combustion for nearly 60 hours, with internal temperatures exceeding 1300°C. Remarkably, no fire suppression system was activated, allowing the test to validate the fire endurance of a single container and the safety performance of CLOU’s Active Ventilation & Explosion-Proof System. No thermal propagation occurred between the adjacent units, underscoring the system’s reliability in dense deployments.

    In recent years, the ESS industry has faced growing concerns over safety, with hundreds of fire and explosion incidents reported globally. As the region with the world’s most comprehensive energy storage safety standards, North America has responded by implementing a rigorous regulatory framework that span full lifecycle risk management—from cell-level to station-wide protection systems. Core standards include NFPA 855, NPFA 68, NFPA 69, UL 9540 and CSA/ANSI C800.

    Guided by these frameworks, CLOU has developed a comprehensive multi-layered fire protection system to safeguard customer assets throughout their lifecycle. This safety system—detailed in the white paper— is based on lean engineering principles and includes:

    Early Warning & Detection of Thermal Runaway – BMS monitors voltage/temperature in real-time, triggering alarms and disconnecting circuits to prevent propagation. Sensors activate active ventilation explosion-proof systems to suppress explosion risks before fires occur.

    Dual-Layer Fire Suppression – CLOU enhances traditional total flooding gaseous fire suppression systems with a water spray addition: it rapidly cools to prevent reignition and syncs with the ventilation system to reduce flammable gas concentration.

    Explosion Protection: Active-Passive Defense – Preemptive Control: Ventilation systems maintain flammable gas concentrations below 25% LEL—preventing explosive conditions at source per NFPA 69. Engineered Venting: Directional pressure-release structures localize blast impacts, preventing chain reactions.

    Active Ventilation & Explosion-Proof Design – integrates five natural exhaust louvers and two intakes to maintain flammable gases below 25% LEL even during single-intake failures (per NFPA 69 verification). The louvers simultaneously serve as pressure-relief vents during explosions, directing flames vertically upward to prevent cross-container propagation, while ensuring continuous ventilation through thermal pressure differences in power outages.

    CLOU’s latest innovations reflect its ongoing commitment to advancing industry safety benchmarks. The white paper is now available for download and serves as a practical reference for developers, EPCs, regulators, and asset owners seeking enhanced safety and long-term system reliability.

    Download the white paper here: https://www.clouess.com/news/317.html

    Video – https://mma.prnewswire.com/media/2737607/CLOU_Aqua_C2_5_59_Hour_Large_Scale_Fire_Test.mp4

    Cision View original content:https://www.prnewswire.co.uk/news-releases/clou-releases-white-paper-on-active-ventilation–explosion-proof-system-following-landmark-59-hour-large-scale-fire-test-302513070.html


    Share. Facebook Twitter Pinterest LinkedIn Tumblr Telegram Email

    Related Posts

    Boao Forum: CRRC Zhuzhou Institute Outlines Core Technologies and Application-Driven Innovation for Green Industry Growth

    August 4, 2026

    Sungrow Powers Sierra Leone’s Energy Transformation with First National-Scale Power Project

    July 31, 2026

    Investec Selects Infosys Finacle SaaS Platform on Microsoft Azure for Digital Banking Transformation

    July 30, 2026
    Latest News

    Australia reforms National Disability Insurance Scheme rules

    August 1, 2026

    India commits 84084 crore rupees to offshore energy security

    August 1, 2026

    Canadian economy grew 0.3% in May report

    August 1, 2026

    Apple market cap reaches 4.94 trillion to top Nvidia

    July 29, 2026
    © 2026 Maghreb Guardian | All Rights Reserved
    • Home
    • Contact Us

    Type above and press Enter to search. Press Esc to cancel.